60 Amp EV Charger - Electrician Talk
2025年1月20日 · As far as wire size, the NEC prohibits installing a 48 amp charger on a 60 amp circuit using #6 romex. #6 romex can handle 55 amp, and normally you could step up to the next available breaker size of 60 amp. But since this is a continuous load, the conductor needs to be able to handle 125% of the load, which is 60 amp. And remember, #6 romex ...
How many amps does it take to trip a 60 amp breaker
2012年4月11日 · Trip curves are available from the manufacturers for all circuit breakers. These can usually be found online. If the running load is 2.2 amperes, there is no way the load would ever be high enough to trip a properly functioning 60 ampere breaker. It sounds like the breaker is oversized and defective.
Replacement Breaker for slyvania type C 60amp - Electrician Talk
2020年4月14日 · So m electrical box in my house holds Sylvania breakers and one of my 2 pole 60 Amp type C breakers quit working on me. I have called a bunch of place around me to get one of them ordered and they are all telling me its 3-6 weeks before they can get them. I was wondering if anyone knew of another breaker that would be a replacement for these.
EV charger - Electrician Talk
2022年7月30日 · People (i.e. DIY) will even put the 1450 outlet on a smaller than 50-amp breaker, and smaller wire, for various "reasons", which can sure enough be fun when they plug in the NEXT greatest thing, one of the plug-in portable 32-amp and 40-amp L2 chargers that are out now, mostly with 1450 plugs.
breakers correspond to awg or mop? | Electrician Talk
2024年12月10日 · A 60 Amp Wall oven wiring and breaker is a violation of 210.18 unless a specific model exists with a higher 60 amp rating. Suspect a Nema 14-50 would cover even very wide double wall ovens. Reactions: Quickservice , Almost Retired and MattM-NC
60 amp Disconnect, 70 amp breaker - Electrician Talk
2009年7月1日 · I am a third year apprentice, in the process of helping to wire a carousel in addition to a fountain. The question is from the pump house for the fountain. There is a 70a breaker that feeds a motor. It goes from the breaker to a non-fusible, 60a disconnect, then to a variable frequency drive, and then to the motor.
8awg copper on a 50 amp breaker - Electrician Talk
2022年10月29日 · Yet there continues to be defects for many others that are doing both the #8 awg, 40 amp breaker, 50 amp receptacle and the #8, 50 amp breaker and 50 amp receptacle. There is no doubt that some of this is related to 2-024, but if the equipment is not permanently installed (hard-wired) it is a crap shoot for the inspector.
600v 60A breaker feeding 30A disconnect. - Electrician Talk
2020年9月10日 · Using a 30 amp fused disconnect is ok in your situation as long as the 60 amp feed has 60 amp wire. Same as feeding a 200 amp panel from the secondary of a transformer that is rated for more than 200 amps. If the panel has a main breaker rated at 200 amps, it’s ok as that is the max load it will have.
Welder branch circuit - Electrician Talk
2010年9月17日 · The circuit breaker should be a 2 pole 60 amp breaker. The receptacle required is almost certain to be a 60 amp pin and sleeve connector body. the exact type should be confirmed with the manufacturer. Probably a Hubbell type, might even be IEC. The circuit will require 2 #6 THHN and a #10 THHN ground.
60 amp sub panel questions - Electrician Talk
2023年8月15日 · Also, I will be needing quite a few circuits and any 60 sub panels I’ve seen available so far are low on the breaker space count. 100 Amp may be the way to go fed with a 60 Amp feeder. Sub panels have a removable neutral grounding screw.